SLZK series clean operating room combined air conditioning unit
The effect of lengthening the connecting pipe of the indoor unit on the cooling capacity (recommended the longest pipe length is 35m)
| Influencing factors | Cooling capacity correction factor | |||||||||
| Equivalent total length of connecting pipe | 5m | 10m | 15m | 25m | 30m | 35m | 40m | 45m | 50m | |
| The outdoor unit is higher than the indoor unit | 0m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 |
| 5m | 1 | 0.98 | 0.96 | 0.92 | 0.90 | 0.88 | 0.86 | 0.84 | 0.82 | |
| 10m | / | 0.97 | 0.95 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | 0.81 | |
| 15m | / | / | 0.94 | 0.90 | 0.88 | 0.86 | 0.84 | 0.82 | 0.80 | |
| 20m | / | / | / | 0.89 | 0.87 | 0.85 | 0.83 | 0.81 | 0.79 | |
| 25m | / | / | / | 0.88 | 0.86 | 0.84 | 0.82 | 0.80 | 0.78 | |
| Indoor unit is higher than outdoor unit | 0m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 |
| 5m | 1 | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
| 10m | / | 0.99 | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
| 15m | / | / | 0.97 | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
| 20m | / | / | / | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
| 25m | / | / | / | 0.93 | 0.91 | 0.89 | 0.87 | 0.85 | 0.83 | |
Table of equivalent lengths of elbows and traps
| Connecting pipe outer diameter mm |
9.52 | 12.7 | 15.88 | 19.05 | 28.6 |
| Elbow m | 0.2 | 0.25 | 0.3 | 0.35 | 0.5 |
| Oil trap m | 1.4 | 1.8 | 2 | 2.4 | 3.7 |
Note: the equivalent pipe length refers to the sum of the length of the straight pipe section of the pipeline plus the equivalent length of the elbow and the trap
Electrical parameter table of outdoor unit of direct expansion combined air handling unit
| Model | SRF8W | SRF12W | SRF16W | SRF20W | SR22W | SR28W | SR33W | SR36W | SR42W | SR48W | SR50W | SR60W | SR66W | SR84W | SR100W | SR210W | SR280W |
| Power supply | 3Ph380 V 50Hz | ||||||||||||||||
| Power cable | 3*2.5+1+2.5 | 3*4+2.5+4 | 3*6+2.5+6 | 3*10+2.5+10 | 3*16+4+16 | 3*50+6+50 | 3*70+10+70 | ||||||||||
Note:
1. The power cord of the unit must be a copper core cable, and the working temperature cannot be greater than its specified value. The recommended wire diameter is to use Google when the operating environment is 40 degrees Celsius.
2. If the length of the power cord is greater than 15 meters, please increase the cross section of the power cord appropriately to avoid accidents caused by overload;
3. The recommended power cord diameter does not consider the auxiliary heater. If the unit is equipped with an auxiliary electric heater, it is necessary to select a copper core cable with a wiring diameter that meets the national standard according to the auxiliary electric heater power to avoid accidents. At the same time, when the actual installation conditions on site are changed, please reduce the capacity according to the specifications of the power cord and circuit breaker provided by the manufacturer.