Data Center Dry Cooler

Products

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Features

Dry coolers are the most cost-effective way to dissipate heat from immersion cooling systems.

Immersion cooling, also known as liquid immersion cooling, submerges computer components or entire servers in a thermally conductive but nonconductive liquid (dielectric coolant), which offers higher heat transfer properties than air and many other advantages.

Benefits:

● Maximum performance, minimum footprint

● High-efficiency geometry

● Modular design, 1~28 fans

● Piping in copper or stainless steel AISI 304 or AISI 316L

● Finned pack available in a wide range of materials

 

Options:

● Coil design refrigerant: water, oil, glycol, BC888, Shell S3X, and so on

● Multiple circuits

● Sub-cooling circuits

● Stainless steel or aluminum casing

● Epoxy resin aluminum or copper fins

● Explosion-proof motor

● Customized fin spacing

Immersion Cooling System for Data Center
                                    Specification
             Dry Cooler Capacity: 500kw 
Oil Inlet/Outlet Temperature: 55℃/40℃
     Ambient Air Temperature: 30 ℃
                              Tank Size: 3.8m*2.3m*1.2mm 
                       Tank Capacity: 96 Pcs S19 
                                               or 128 Pcs DELL C6220 Server 
        SS304 Material for Tank, Pipe, Flange
       (Specific size and material customizable)

Immersion Container System

Integral type, our customers can directly connect the pipes to use, because we put all the tanks, pumps, controllers, software, etc. in one container.

Experienced and professional engineers, passionate R&D teams, competitive price with good quality, and cooperation experience with customers from all over the world.

Immersion Container

All the tanks, pumps, controllers, software, etc. can all be put into a 20GP container through connecting pipes.
Each container can hold up to 120 mining machines, a total of 2 20GP containers, and 240 mining machines.
The total heat exchange capacity is 900-960KW.
In our solution, the coolant enters the dry cooler directly from the tank.
We use pumps and hoses, and no plate heat exchangers.
Customized for different coolants, including BC888, dielectric fluid, Shell S3X, S5X, etc.

Immersion Tank System

The dry cooler and the immersion tank are linked together through liquid pipes.

After the coolant flows out of the dry cooler, it cools the mining machine in the immersion tank through the inlet pipe which has small holes, and then returns to be cooled again through the red water outlet pipe.

Immersion Tank

A Immersion tank includes drainage channels, switches, PDU sockets and a power distribution box.

Dry Cooler is an efficient and energy-saving application device for data centers, designed to effectively reduce the temperature and provide continuous and stable cooling. It utilizes dry cooling technology, eliminating the need for cooling water compared to traditional water cooling systems, thereby avoiding water waste and the cost of water treatment. By using ambient air as the primary cooling medium and circulating it with fans, Dry Cooler dissipates heat from the data center, ensuring that the internal temperature remains within a safe range.

Dry Cooler offers several significant advantages:

1. Energy Efficiency: Compared to traditional water cooling systems, Dry Cooler does not require a significant amount of electricity to operate cooling pumps and other equipment, resulting in substantial energy cost reduction for data centers.

2. Reliability and Stability: With advanced heat dissipation technology, Dry Cooler evenly dissipates heat into the surrounding environment, ensuring a stable temperature within the data center and preventing damage to hardware due to overheating.

3. Environmental Sustainability: As Dry Cooler does not use cooling water, data centers no longer require excessive water resources, thereby avoiding water waste and the cost of water treatment. Additionally, Dry Cooler can reduce the use of air conditioning systems, further lowering consumption of fossil fuels and effectively reducing carbon emissions.

4. Flexibility and Scalability: Dry Cooler is compactly designed and occupies minimal space, making it suitable for data centers of various sizes. It can be installed and arranged flexibly, even in limited spaces. Moreover, Dry Cooler can be expanded according to specific requirements to meet the growing demands of data processing.

5. Easy Maintenance: Dry Cooler features a simple structural design that is easy to maintain and clean. There is no need for frequent replacement of cooling media, reducing the complexity and cost of maintenance work.

 

Downloads